QuickSearch:   Number of matching entries: 0.

AuthorTitleYearJournal/ProceedingsReftypeDOI/URL
Amatucci, W.E., Schuck, P.W., Walker, D.N., Kintner, P.M., Powell, S., Holback, B. & Leonhardt, D. Contamination-free sounding rocket Langmuir probe. 2001 Review of Scientific Instruments
Vol. 72(4), pp. 2052 
article URL 
Azooz, A.A. Four free parameter empirical parametrization of glow discharge Langmuir probe data. 2008 Review of Scientific Instruments
Vol. 79(10), pp. 103501 
article URL 
Boedo, J., Gunner, G., Gray, D. & Conn, R. Robust Langmuir probe circuitry for fusion research. 2001 Review of Scientific Instruments
Vol. 72(2), pp. 1379 
article URL 
Brandt, C., Testrich, H., Kozakov, R. & Wilke, C. Investigation of the disturbance of a Langmuir probe and its influence on measurement results. 2006 Review of Scientific Instruments
Vol. 77(2), pp. 023504 
article URL 
Calderón, E., Hidalgo, C., Pedrosa, M.A. & Silva, C. On the interpretation of fluctuation and E×B turbulent transport measured by Langmuir probes in fusion plasmas. 2004 Review of Scientific Instruments
Vol. 75(10), pp. 4293 - 4295 
article URL 
Chiodini, G., Riccardi, C. & Fontanesi, M. A 400 kHz, fast-sweep Langmuir probe for measuring plasma fluctuations. 1999 Review of Scientific Instruments
Vol. 70(6), pp. 2681 
article URL 
DeJoseph Jr., C.A. & Demidov, V.I. Diode calibration of a Langmuir probe system for measurement of electron energy distribution functions in a plasma. 2005 Review of Scientific Instruments
Vol. 76(8), pp. 086105 
article URL 
Deline, C., Gilchrist, B.E., Dobson, C., Jones, J.E. & Chavers, D.G. High accuracy plasma density measurement using hybrid Langmuir probe and microwave interferometer method. 2007 Review of Scientific Instruments
Vol. 78(11), pp. 113504 
article URL 
Gerhardt, S.P., Anderson, D.T., Anderson, F.S.B. & Talmadge, J.N. Electrode and Langmuir probe tools used for flow damping studies in the Helically Symmetric Experiment. 2004 Review of Scientific Instruments
Vol. 75(11), pp. 4621 - 4628 
article URL 
Grigull, S., Foltyn, S., Hollander, M., Evans, C. & Nastasi, M. Setup for in situ x-ray diffraction and ion-channeling studies of.. 1999 Review of Scientific Instruments
Vol. 70(9), pp. 3656 
article URL 
Guttenfelder, W., Lechte, C., Koepke, M.E. & Demidov, V.I. Utility of a baffled Langmuir probe for applications to edge plasma and turbulence characterization in stellarator plasma. 2004 Review of Scientific Instruments
Vol. 75(10), pp. 3622 - 3624 
article URL 
Hartfuss, H., Brakel, R., Endler, M., Geist, T., Grigull, P., Hofmann, J., Junker, J., Kick, M., Kuhner, G., Niedermeyer, H., Ringler, H., Teubel, A., Wagner, F. & Weller, A. Diagnostic strategy of the W7-X stellarator. 1997 Review of Scientific Instruments
Vol. 68(2), pp. 1244 
article URL 
Hartfuss, H.J., Brakel, R., Endler, M., Geist, T., Grigull, P., Hofmann, J.V., Junker, J., Kick, M., Kuhner, G., Niedermeyer, H., Ringler, H., Teubel, A., Wagner, F. & Weller, A. Diagnostic strategy of the W7-X stellarator (abstract). 1997 Review of Scientific Instruments
Vol. 68(1), pp. 888 
article URL 
Hoegy, W.R. & Brace, L.H. Use of Langmuir probes in non-Maxwellian space plasmas. 1999 Review of Scientific Instruments
Vol. 70(7), pp. 3015 
article URL 
Jauberteau, J.L. & Jauberteau, I. Electron energy distribution function in plasma determined using numerical simulations of multiple harmonic components on Langmuir probe characteristic—Efficiency of the method. 2007 Review of Scientific Instruments
Vol. 78(4), pp. 046102 
article URL 
Jaworski, M.A., Kallman, J., Kaita, R., Kugel, H., LeBlanc, B., Marsala, R. & Ruzic, D.N. Biasing, acquisition, and interpretation of a dense Langmuir probe array in NSTX. 2010 Review of Scientific Instruments
Vol. 81(10), pp. 10E130 
article URL 
Jeon, S.J., Eom, G.S., Kim, J.H. & Choe, W. Multichannel rf-compensated Langmuir probe array driven by a single bias supply. 2002 Review of Scientific Instruments
Vol. 73(2), pp. 277 
article URL 
Kallman, J., Jaworski, M.A., Kaita, R., Kugel, H. & Gray, T.K. High density Langmuir probe array for NSTX scrape-off layer measurements under lithiated divertor conditions. 2010 Review of Scientific Instruments
Vol. 81(10), pp. 10E117 
article URL 
Kene´z, L., Biri, S., Kara´csony, J., Valek, A., Nakagawa, T., Stiebing, K.E. & Mironov, V. Diagnostic research of plasmas generated by a 14.5 GHz ECR ion source using Langmuir-probe. 2002 Review of Scientific Instruments
Vol. 73(2), pp. 617 
article URL 
Klenzing, J. & Rowland, D. The fixed-bias Langmuir probe on the Communication/Navigation Outage Forecast System satellite: Calibration and validation. 2012 Review of Scientific Instruments
Vol. 83(11), pp. 114501 - 114501-5 
article URL 
Klindworth, M., Arp, O. & Piel, A. Langmuir probe system for dusty plasmas under microgravity. 2007 Review of Scientific Instruments
Vol. 78(3), pp. 033502 
article URL 
König, R., Ramasubramanian, N., McCormick, K., Grigull, P., Gadelmeier, F., Wenzel, U., Schweer, B. & Brix, M. Island divertor spectroscopy at the Wendelstein W7-AS stellarator. 2003 Review of Scientific Instruments
Vol. 74(3), pp. 2052 
article URL 
LaBombard, B. & Lyons, L. Mirror Langmuir probe: A technique for real-time measurement of magnetized plasma conditions using a single Langmuir electrode. 2007 Review of Scientific Instruments
Vol. 78(7), pp. 073501 
article URL 
Laubé, S., Mostefaoui, T. & Rowe, B. Continuous heatable Langmuir probe for flowing afterglow measurements. 2000 Review of Scientific Instruments
Vol. 71(2), pp. 519 
article URL 
Lee, S.G. & Bak, J.G. Triple Langmuir probe measurements in the Hanbit magnetic mirror device. 2001 Review of Scientific Instruments
Vol. 72(1), pp. 442 
article URL 
Li, M., Xiang, W., Xiao, K.X. & Chen, L. Dynamical changes of ion current distribution for a Penning discharge source using a Langmuir probe array. 2012 Review of Scientific Instruments
Vol. 83(2), pp. 02B722 
article URL 
Lobbia, R.B. & Gallimore, A.D. High-speed dual Langmuir probe. 2010 Review of Scientific Instruments
Vol. 81(7), pp. 073503 
article URL 
Magnus, F. & Gudmundsson, J.T. Digital smoothing of the Langmuir probe I-V characteristic. 2008 Review of Scientific Instruments
Vol. 79(7), pp. 073503 
article URL 
Martin, A.K. & Koelfgen, S.J. A maximum-likelihood algorithm for reduction of Langmuir probe data. 2007 Review of Scientific Instruments
Vol. 78(10), pp. 103508 
article URL 
Nakashima, Y., Islam, M.K., Natori, T., Katanuma, I., Ohki, T., Watanabe, K., Higashizono, Y., Cho, T. & Ishimoto, Y. Edge plasma measurements near the minimum-B anchor cell of GAMMA10 using Langmuir probe and calorimeter arrays. 2004 Review of Scientific Instruments
Vol. 75(10), pp. 4308 - 4310 
article URL 
Oh, S.-J., Oh, S.-J. & Chung, C.-W. Radio frequency-compensated Langmuir probe with auxiliary double probes. 2010 Review of Scientific Instruments
Vol. 81(9), pp. 093501 
article URL 
Ohkuni, K. & Toi, K. Study of structural effects of Langmuir probe array on edge fluctuation measurement in the compact helical system heliotron/torsatron. 2001 Review of Scientific Instruments
Vol. 72(1), pp. 446 
article URL 
Ohkuni, K., Toi, K., Ohdachi, S. & Takagi, S. Langmuir probe array for edge plasma study on the compact helical system heliotron/torsatron. 1999 Review of Scientific Instruments
Vol. 70(1), pp. 419 
article URL 
Ohshima, S., Yamamoto, S., Takeuchi, M., Nagasaki, K., Mizuuchi, T., Okada, H., Minami, T., Kobayashi, S., Hanatani, K., Konoshima, S. & Sano, F. Multichannel Langmuir probe for turbulence study in Heliotron J. 2010 Review of Scientific Instruments
Vol. 81(10), pp. 10E137 
article URL 
Olson, J., Brenning, N., Wahlund, J.-E. & Gunell, H. On the interpretation of Langmuir probe data inside a spacecraft sheath. 2010 Review of Scientific Instruments
Vol. 81(10), pp. 105106 
article URL 
Oyama, K.-I., Lee, C.H., Fang, H.K. & Cheng, C.Z. Means to remove electrode contamination effect of Langmuir probe measurement in space. 2012 Review of Scientific Instruments
Vol. 83(5), pp. 055113 
article URL 
Patterson, J.R., Emig, J.A., Fournier, K.B., Jenkins, P.P., Trautz, K.M., Seiler, S.W. & Davis, J.F. A Langmuir probe diagnostic for time-of-flight measurements of transient plasmas produced by high-energy laser ablation. 2012 Review of Scientific Instruments
Vol. 83(10), pp. 10D725 - 10D725-3 
article URL 
Pedrosa, M., Lopez-Sanchez, A., Hidalgo, C., Montoro, A., Gabriel, A., Encabo, J., de la Gama, J., Martinez, L., Sanchez, E., Perez, R. & Sierra, C. Fast movable remotely controlled Langmuir probe system. 1999 Review of Scientific Instruments
Vol. 70(1), pp. 415 
article URL 
Pilling, L.S., Bydder, E.L. & Carnegie, D.A. A computerized Langmuir probe system. 2003 Review of Scientific Instruments
Vol. 74(7), pp. 3341 
article URL 
Riccardi, C., Longoni, G., Chiodini, G. & Fontanesi, M. Comparison between fast-sweep Langmuir probe and triple probe for fluctuations measurements. 2001 Review of Scientific Instruments
Vol. 72(1), pp. 461 
article URL 
Rudakov, D.L., Boedo, J.A., Moyer, R.A., Lehmer, R.D., Gunner, G. & Watkins, J.G. Fast electron temperature diagnostic based on Langmuir probe current harmonic detection on DIII-D. 2001 Review of Scientific Instruments
Vol. 72(1), pp. 453 
article URL 
Rudakov, D.L., Boedo, J.A., Moyer, R.A., Stangeby, P.C., McLean, A. & Watkins, J.G. Effect of electron temperature fluctuations on slowly swept Langmuir probe measurements. 2004 Review of Scientific Instruments
Vol. 75(10), pp. 4334 - 4337 
article URL 
Schmitzer, C., Kronberger, M., Lettry, J., Sanchez-Arias, J. & Störi, H. Plasma characterization of the superconducting proton linear accelerator plasma generator using a 2 MHz compensated Langmuir probe. 2012 Review of Scientific Instruments
Vol. 83(2), pp. 02A715 
article URL 
Schubert, M., Endler, M. & Thomsen, H. Spatiotemporal temperature fluctuation measurements by means of a fast swept Langmuir probe array. 2007 Review of Scientific Instruments
Vol. 78(5), pp. 053505 
article URL 
Sicard, P., Boucher, C., Litnovsky, A. & St-Germain, J.-P. A compact and portable PC-based Gundestrup–Langmuir probe diagnostic system. 2005 Review of Scientific Instruments
Vol. 76(1), pp. 013505 
article URL 
Sreenivasulu, M., Patra, S.K. & Rao, G.M. Powered automatic measuring system for Langmuir probe plasma analysis. 2001 Review of Scientific Instruments
Vol. 72(11), pp. 4312 
article URL 
Srivastava, P.K., Singh, S.K., Awasthi, L.M. & Mattoo, S.K. Revisiting plasma hysteresis with an electronically compensated Langmuir probe. 2012 Review of Scientific Instruments
Vol. 83(9), pp. 093504 - 093504-5 
article URL 
Steigies, C.T. & Barjatya, A. Contamination effects on fixed-bias Langmuir probes. 2012 Review of Scientific Instruments
Vol. 83(11), pp. 113502 
article URL 
Watkins, J.G., Rajpal, R., Mandaliya, H., Watkins, M. & Boivin, R.L. Embedded calibration system for the DIII-D Langmuir probe analog fiber optic links. 2012 Review of Scientific Instruments
Vol. 83(10), pp. 10D710 - 10D710-3 
article URL 
Watkins, J.G., Taussig, D., Boivin, R.L., Mahdavi, M.A. & Nygren, R.E. High heat flux Langmuir probe array for the DIII-D divertor plates. 2008 Review of Scientific Instruments
Vol. 79(10), pp. 10F125 
article URL 
Weaver, I., Martin, G., Graham, W., Morrow, T. & Lewis, C. The Langmuir probe as a diagnostic of the electron component within low temperature laser ablated.. 1999 Review of Scientific Instruments
Vol. 70(3), pp. 1801 
article URL 
Wendt, A.E. Passive external radio frequency filter for Langmuir probes. 2001 Review of Scientific Instruments
Vol. 72(7), pp. 2926 
article URL 
Wild, J., Kudrna, P., Gronych, T., Broz, J., Zelinger, Z., Kubát, P. & Civis, S. Langmuir probe measurement of plasma splitting during pulsed laser deposition. 2001 Review of Scientific Instruments
Vol. 72(2), pp. 1597 
article URL 

Created by JabRef on 26/03/2014.